Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Some of the pictures in this manual are a bit irritating. I had to dissassemble the unit and some of the screws have different threads, which is not mentioned in this manual. Also some of the drawings of the boards look different than the actual boards.
After all, the manual was very useful. I was able to recalibrate the capstan drive and it is working fine again.
 ;
This manual is very good. 303 pages scanned in a very high resolution. My camera has bad, leaking capacitors which all of the V5000 models are suffering from these days.
There is a huge part list with all capacitors, transistors etc. in this manual which helped me a lot. Otherwise I would not have been able to buy replacement parts.
The dissassembly guide is very enormous and detailed. Unlike on the Panasonic MS1 manual I downloaded here it actually looks like the real parts look. And the screws are labeled correctly, so you shouldn't have any left after the repair. ;)
 ;
has all the schematics you could need,and very well laid out format also has all part numbers along with an exploded view which is helpful
 ;
Very nice to have! Now it is no problem to understand how it is put together.
Helps me a lot.
 ;
good scans, all is clear. all pages in order. recommended
HORIZONTAL DEFLECTION CIRCUIT DEFECTS
Power supply voltages are OK. There is no high voltage
Check 15V at the collector of T503.
NO
Check and replace R503 and TR501 Hor. Driver transformer
YES
Check the voltages 1.42 VDC and 0.92 VAC at + pin of C502
NO
Check voltage 8V at pin 9, 39 of IC101. If present replace IC101.
YES
Check the voltages 0.28 VDC, 0.92 VAC and 15625 Hz signal at the base of T503.
NO
Check and replace D505 and C503.
YES
Remove T504. Check the voltage 145 VDC at the collector point.
NO
Check and replace R525 and Line Output Transformer.
YES
Check 2 VAC at the base of T504.
NO
Check and replace T503, TR501 and R513.
YES
Check and replace D507, D508, C518, C519, C521. Place T504 to its position. Check the operation of Line Output Transformer.
NO
Replace Line Output Transformer.
YES
There is a noise heard from Line Output Transformer. Check and replace T501, R516 and C520.
|
|
 |
> |
|